Intake Systems

GE Frame 7 Turbine Inlet Filterhouse Upgrade

Intake systems are provided to customer specifications. LoTec will work extremely close with their customer to make sure every requirement is met. Design parameters include pressure drop, filtration efficiency, and volume flow. Specific components such as humidity control, evaporative-cooling, and mass flow augmentation can be added to meet a specific goal. In addition, if there is compressor bleed-air available, LoTec can provide anti-icing at the inlet filter.

Intake Filter Systems

Intake with Mechanical Chiller System

Not all applications are created equal; however, the goal of all filters is: Keep the dirt out! The most common type of filter is a barrier type, which typically is just an element with a pre-filter that sits in some type of a holding frame. They come in various styles and configurations relative to the media and replacement schemes. In addition, they tend to be less money per CFM and thus more common.

There is no such thing as a filter that gets out everything, though. That is why LoTec suggests a wash system. However, wash systems are not a substitution for filtration.

Pulse Clean Systems

Pulse Cleaning Intake System for Orenda OGT2500 BioFuel Gas Turbine

Desert environments typically have a high dust load in the air, which is made up of larger particles that are dry. An effective filter for this application is a pulse cleaning system. However, dry is the key word because if you have moisture or industrial emissions, ie: vehicular traffic, you introduce pollutants into the air that create a sticky ‘dirt cake.’ Dirt cakes will not pulse-off as well, degrading the value of the pulse filter system. Pulse clean filters are also good in an environment that has frost. Light frost can be pulsed-off the media, allowing for lower operating pressure drops in cold/frosty conditions. Therefore, LoTec will work very close with their customers to ensure they receive the optimum system for their situation.

Feel free to call if you would like to discuss your particular pulse filtration situation, LoTec would be happy to get you some help. (972) 462-7884.

Enclosures

LM2500 Turbine Enclosure

Equipment enclosures are an essential element to an overall quiet system. LoTec designs equipment that ranges from tight fitting, skid based enclosures to large buildings that go around the equipment and are free standing to grade. Their construction can vary from the acoustical metal building type to the heavier seal-welded plate and perforated metal type. Skid based units tend to be limited to shipping sizes, while off-skid enclosures are not as limited in size. LoTec can modify an existing enclosure or start from scratch and create a signature enclosure depending on the customer’s needs.

Feel free to call if you would like to discuss your particular enclosure situation, LoTec would be happy to get you some help. (972) 462-7884.

Rolls Royce Enclosures

EGT Turbine Enclosures

Pratt & Whitney FT4 Turbine Enclosure

Equipment enclosures are an essential element to an overall quite system. LoTec designs equipment that ranges from tight fitting, skid based enclosures to large buildings that go around the equipment and are free standing to grade. Their construction can vary from the acoustical metal building type to the heavier seal-welded plate and perforated metal type. Skid based units tend to be limited to shipping sizes, while off-skid enclosures are not as limited in size. LoTec can modify an existing enclosure or start from scratch and create a signature enclosure depending on the customer’s needs.

Feel free to call if you would like to discuss your particular enclosure situation, LoTec would be happy to get you some help. (972) 462-7884.

Turbine Intake, Exhaust, & Enclosure System for Portable CoGen Package

Equipment enclosures are an essential element to an overall quite system. LoTec designs equipment that ranges from tight fitting, skid based enclosures to large buildings that go around the equipment and are free standing to grade. Their construction can vary from the acoustical metal building type to the heavier seal-welded plate and perforated metal type. Skid based units tend to be limited to shipping sizes, while off-skid enclosures are not as limited in size. LoTec can modify an existing enclosure or start from scratch and create a signature enclosure depending on the customer’s needs.

Feel free to call if you would like to discuss your particular enclosure situation, LoTec would be happy to get you some help. (972) 462-7884.

Exhausts

Exhaust systems come in many shapes; however, generally they are vertical or horizontal. Included in these systems are expansion joints, silencers, ductwork stacks, CO catalyst beds, SCR catalyst beds, ladders, platforms, and structural steel. Specific design can meet any combination of specifications: acoustics, pressure drop, etc., depending on the customer requirements. Our experience allows us to provide the right design for your application.

Feel free to call if you would like to discuss your particular exhaust situation, LoTec would be happy to get you some help. (972) 462-7884.

Pratt & Whitney FT8 Exhaust Stack

Pratt & Whitney FT8 Exhaust Transition

Westinghouse 251 Exhaust Stack

GE Frame 7 Exhaust Stack

GE Frame 7 Exhaust Stacks

Rolls Royce Exterior Cladded Exhaust Elbow

Solar Centaur 40 Exhaust Stack Reactive & Absorptive Silencer

Stainless-Steel-Constructed-Solar-Saturn-T1300-Absorptive-Silencers

Stainless Steel Construction Solar Saturn T1300 Absorptive Silencers with Bullet

EGT Exhaust Eductors

Additional Silencers

Stainless Steel Constructed - CO2 Blow Down Silencer

Noise ranging from engine exhausts to starters can be a huge headache for both site managers and local neighbors. That is why LoTec offers a variety of silencer products that are usually site specific. Our specialists can visit the site and determine the best solution or meet a specification given by the customer. Whether the sound originates in the high frequency or the low, we have a silencer to offer.

Feel free to call if you would like to discuss your particular silencer situation, LoTec would be happy to get you some help. (972) 462-7884.

Ventilation Systems

CAT 3616 Power Plant Upgrade
Design Noise Reduction 15 dBA
Utilizing inlet and discharge silencers and ventilation extraction fans

Virtually every enclosure needs some type of air movement, which is why LoTec also provides ventilation systems. Depending on the application, the system can include filtration, silencing, fans, louvers, volume control, dampers, and more. The amount of noise reduction, pressure loss, and construction geometry are varied to match the individual project needs.

Feel free to call if you would like to discuss your particular ventilation system situation, LoTec would be happy to get you some help. (972) 462-7884.